Monroe 268A-1T 静电消除检测仪 (可调整时间)
• Meets ESD Association Standard ANSI / ESD STM 3.1
• Removable, cable-connected plate/ probe permits precise positioning and remote monitoring
• Separate time and voltage displays for decay rate analysis
• Recorder output for permanent records and unattended operation
• Two ranges measure from 0 to ±5kV
• Dramatically demonstrates induced charges and human body potential
It’s ability to display peak positive and negative offset voltage swings make it the ideal tool to quickly and accurately balance pulsed-DC ionization systems. The detachable ion collecting plate can be placed at the work height or placed within process equipment to evaluate ionizers while in use. Model 268A-1T incorporates an adjustable stop voltage for decay tests to accommodate specialized needs. This option allows the user to set the timer stop voltage at any level from 0 V to 1000 V.
	
 
	 
	
		
			
 
				 
			
					Charged Plate/Probe Assembly 
			
				
				 
			
					Capacitance of total discharge test circuit with plate: 
				
				
					20 ±2 picofarads 
			
				
				 
			
					Plate self-discharge rate: 
				
				
					<10% at 1 KV within 5 minutes 
			
				
				 
			
					Dimensions: 
				
				
					6 x 6 inches (15.2 x 15.2 cm) 
			
				
				 
			
					Power Supply 
			
				
				 
			
					Maximum output: 
				
				
					±6000 volts 
			
				
				 
			
					Available plate charging voltages: 
				
				
					±1000 V and ±5000 V, continuously adjustable from 1100 to >5000 V 
			
				
				 
			
					Electrostatic Fieldmeter 
			
				
				 
			
					Ranges selectable: 
				
				
					0 to ±5000 V, 0 to ±2000 V 
			
				
				 
			
					Accuracy: 
				
				
					Better than 2% 
			
				
				 
			
					Drift: 
				
				
					<0.4% per hour, noncumulative after 10 minutes stabilization, TYP. 
			
				
				 
			
					Speed of response: 
				
				
					<100 msec from 10% to 90% of full scale in either range 
			
				
				 
			
					Bandwidth: 
				
				
					6 Hz 
			
				
				 
			
					Output: 
				
				
					1/1000 of plate voltage 
			
				
				 
			
					Timer 
			
				
				 
			
					Limits: 
				
				
					1.0 kV/100 V or 5.0 kV/500 V (user selectable) 
			
				
				 
			
					Max time measured: 
				
				
					999.9 sec (16 minutes +) 
			
				
				 
			
					Resolution: 
				
				
					0.1 sec 
			
				
				 
			
					Complete Instrument 
			
				
				 
			
					Power requirements:
				 
				
					117 or 220 VAC ±10%, 50/60 Hz (factory preset), 5 watts
				 
			
				 
			
					Dimensions:
				 
				
					6¾ x 6¾ x 9½ inches (17 x 17 x 24cm)
				 
			
				 
			
					Weight:
				 
				
					5.5 lbs (2.3 kg)
				 
			
				 
		
	
					Accessories:
				 
				
					Manual
				 
			
	
Two operating modes cover all types of ionization systems.
For room and table-top ionization systems, laminar flow hoods, and air guns and nozzles the normal (discharge) mode provides both static decay timing and system balance monitoring.
For pulsed DC ionization systems the peak mode monitors voltage swings by reading and holding the peak voltage and polarity (positive or negative) sensed on the charged plate/potential.
 
				



 
					
							 
					
							 
					
							 
					
							 
					
							