Monroe 288B 静电消除检测仪
• Meets ESD Association Standard ANSI / ESD STM 3.1
• Fully configurable operating parameters
• Soft keys for highly intuitive programming
• Manual and automated testing of Decay and Balance
• Internal storage for up to 1500 tests, 500 locations and 4 test protocols
• Internal battery for portable operation (also line operated)
• Large, easy to read, high contrast LCD display
• Detachable 6” x 6” plate (Optional plate 1” X 1” plate available)
• RS232 interface
• Built in temperature and humidity sensors
• Auto-ranging to 0.1V resolution below 100V
• Compatible with optional 288B Graphing Software
Soft keys simplify the programming and operation of automated tests. Upload test set-ups and ionizer locations. Download stored test results, including environmental data captured by integral temperature and relative humidity sensors. The Model 288B uses a novel voltage-follower measurement technique to increase stability, bandwidth, and accuracy, making it ideal for testing the most modern critical-balance ionizers.
	 
	 
						240 x 64 character/graphic
					 
						    Voltage – Accuracy Resolution: 3½ digit display (Decay and Peak reading) ±0.1% of reading ±3 V 1 volt 
					 
						    Balance -:                  0.1 volt for readings < 150 volts
					 
						    Time – Accuracy Resolution: 4 digit display 0.1% of reading ±1 lsd 0.1 second for readings < 1000 seconds 1 second for reading > 999 seconds 
					 
						Electrometer
					 
						Dynamic range: ±1200 volts
					 
						Follower error: < 10 mV
					 
						Speed of Response: <10 msec for 1 kV to 0 volts (90%-10%)
					 
						Bandwidth: -3db @ 1Khz 20Vp-p
					 
						                    -3db @ 10Hz 2000Vp-p 
					 
						Noise: < 12 mV rms
					 
						Divide by 200
					 
						    Accuracy: 0.1% of reading ±1 mV Refer to Output
					 
						    Output Impedance: 1K ohm
					 
						1000 volts Standard
					 
						    Range: ±10 to ±1000 volts
					 
						    Resolution: Settable to 1 volt
					 
						    Accuracy: 0.3% of setting ±2.5 volts
					 
						100 volts Standard
					 
						    Range: 0- ±995 volts
					 
						    Resolution: Settable to 1 volt
					 
						    Accuracy: 0.3% of setting ±2.5 volts
					 
						Range: 10 to 100 volts above the start voltage
					 
						Resolution: Settable to 1 volt increments
					 
						Accuracy: 0.3% of setting ±2.5 volts
					 
						Capacitance: 20 pF ±2pf
					 
						Zero Drift: < 100 mV/sec (no incident ion flow)
					 
						Self Discharge: < 200 mV/sec
					 
						Range: 0 - 50°C
					 
						Accuracy: ±2°C typ
					 
						Range: 10% - 80% RH @ 25°C
					 
						Accuracy: ±5% typ
					 
						Temperature: 5°C to 35°C
					 
						Humidity: to 80%, non condensing
					 
						Battery life: Typ > 6 hrs
					 
						Charge Time: < 8 hrs to > 90% capacity
					 
						Power
					 
						Voltage: 90 - 250 VAC 50/60 Hz
					 
						Wattage: < 12 watts operating
					
		
			
 
				 
			
					Display 
				
				
					 
			
				 
			
					 
				
					 
			
				 
			
					Monitor output 
				
				
					 
			
				 
			
					Start Voltages 
				
				
					 
			
				 
			
					Stop Voltages 
				
				
					 
			
				 
			
					Charge Voltage 
				
				
					 
			
				 
			
					Charge Plate 
				
				
					 
			
				 
			
					Peak Detector 
				
				
					(Balance Test) Bandwidth: <10HZ 
			
				
				 
			
					Temperature Sensor 
				
				
					 
			
				
				 
			
					Humidity Sensor 
				
				
					 
			
				 
			
					Operating
				 
				
					 
			
				 
			
					 
				
					 
			
				 
			
					Data Storage
				 
				
					1500 Readings
				 
			
				 
			
					CPM
				 
				
					Size: 11” x 9” x 6” (280 x 229 x 152 mm)
				 
			
				 
		
	
					Weight
				 
				
					12½lb. (5.7kg)
				 
			
- NEW: Auto Ranging to 0.1V resolution below 100V
- NEW: Compatible with Monroes Optional New 288B Graphing Software
- Test all types of Ionizers
- Automated testing reduces ionizer test time and data logging time
- Adjustable start and stop voltages for decay test accommodate specialized needs
- Large, easy-to-read, high-contrast LCD display
- Detachable ion collecting plates can be placed at the work height or placed within process equipment to evaluate ionizers while in use
- Small ion collecting plates are available to permit measurements in confined spaces
- LED bar graph shows balance voltage in real time
 
				



 
					
							 
					
							 
					
							 
					
							 
					
							